A thermal fluid-dynamic transient analysis of the EADF down-comer channel

dc.contributor.authorAragonese, Cosimo
dc.contributor.authorBuono, Stefano
dc.contributor.authorFotia, Giorgio
dc.contributor.authorMaciocco, Luca
dc.contributor.authorMoreau, Vincent
dc.contributor.authorSorrentino, Luca
dc.date.accessioned2014-06-10T09:27:31Z
dc.date.available2014-06-10T09:27:31Z
dc.date.issued2000-12-05
dc.description.abstractIn this work a numerical simulation of the downcomer channel of the Energy Amplifier Demonstration Facility (EADF) [1, 2] is presented. The simulation is fully three-dimensional (3D) and is focused on a transient analysis. All relevant heat transfer phenomena are taken into account. Starting from the nominal power configuration, we have simulated the response of the system to a power shutdown of the core for a period of 60 s. The core shutdown is simulated imposing a linear variation of the inlet flow temperature from 400°C to 305°C in 10 s. The simulation shows the evolution of the thermal stratification outside the IHX and the evolution of the IHX operation.IT
dc.identifier.urihttp://hdl.handle.net/11050/1008
dc.language.isoenIT
dc.subjectenergy amplifier demonstration facility (EADF)IT
dc.subjectCFDIT
dc.subject3D simulationIT
dc.subject.een-cordisEEN CORDIS::ENERGIA::Fissione nucleare / fusione nucleare::Fissione nucleare / fusione nucleareIT
dc.titleA thermal fluid-dynamic transient analysis of the EADF down-comer channelIT
dc.typeReportIT
File
Original bundle
Ora in mostra 1 - 1 di 1
Caricamento...
Immagine di anteprima
Nome:
2843.pdf
Dimensione:
3.74 MB
Formato:
Adobe Portable Document Format
Descrizione:
Report
License bundle
Ora in mostra 1 - 1 di 1
Caricamento...
Immagine di anteprima
Nome:
license.txt
Dimensione:
2.06 KB
Formato:
Item-specific license agreed upon to submission
Descrizione:
collections